CVOC REMEDIATION STRATEGY EVALUATION PRS Deployment Units: Simple Additive Delivery Approach Former Textile Manufacturing Facility, Hamilton, Ontario Canada
Posted October 7, 2026

BACKGROUND: Former textile mill with continuous operations from early 1800’s through 1960’s. Past use of the solvent Tetrachloroethylene (PCE) adversely impacted Site groundwater with PCE. Trichloroethylene (TCE) and cis-1, 2-Dichloroethylene (cis-DCE) were also documented in 2010 above Ontario Ministry of Environment (MOE) Table 3 SCS standards..

BASELINE: PoPCE 43,000 μg/Kg (micrograms per kilogram) in saturated soils proximate to MW-9 and the source zone contaminants. TCE and cis-DCE 1.4 μg/Kg and 0.5 μg/Kg, respectively. PCE in groundwater at MW-9 120,000 μg/Liter with TCE and cis-DCE 700 μg/Kg, and 560 μg/Kg, respectively.

RESULTS: ERDEnhanced™amended groundwater realized:

  • 98% REDUCTION in PCE
  • 95% REDUCTION in TCE
  • 80% REDUCTION in cis-DCE with no rebound and no detectable concentrations of Vinyl chloride (VC)

Download full case study here.