BACKGROUND: PHC contaminants as residual mass sorbed to soil with dissolved-phase migration from the USTs into adjacent native soils. Groundwater on- and off-site are adversely impacted by Gasoline Range and Diesel Range Organics (GRO/DRO), both residual and dissolved-phase, extending from 10ft to 30ft bgs. Fluctuating groundwater creating vertical smear zone >10ft; downgradient plume extending >60ft from source area.
RESULTS: Groundwater additive availability peaked as HPC densities and Nitrates (NO3) decreased to below baseline 4-months post injection. Over next 10-months groundwater monitoring recorded additive levels and bulk water microbial densities remained below detection levels (BDL) however, during this same period dissolved-phase concentrations GRO/BTEX decreased by 93.5% and 98.7% from peak bioavailability, respectively.
Download full case study here.