BACKGROUND: Former industrial facility with Trichloroethylene (TCE) in groundwater at ≈30% solubility, indicating significant DNAPL. TCE is the ‘parent’ cVOC contaminant.
PROCESS: 20-months evaluation; three monitoring wells amended using additive filled Passive Release Sock (PRS) deployment units; fourth, a monitored control. PRS units are suspended in saturated casing volume of test well, remaining 6-8 weeks, then replaced periodically to maintain additive residency time. BioTraps® were deployed in each monitoring well; groundwater monitoring/sampling performed with each replacement.
RESULTS: 20-months post additive deployment, amended wells averaged 98.5% reduction in parent-parent/daughter ratios with secondary lines of evidence to support additive enhanced reductive dechlorination. Observations include temporal increases in carbon, expedited alternative electron scavenging, and general increases in ethene concentrations at each amended well. At MW-38A, >99.9% reduction in parent [TCE] was realized.
Download full case study here.